Skip to main content
Enterprise AI Analysis: CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images

Enterprise AI Analysis

CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images

Authored by Alexandre St-Georges et al. | Published: October 28, 2025

This paper introduces a groundbreaking approach to enhance Positron Emission Tomography (PET) imaging by eliminating the need for traditional Computed Tomography (CT) scans for attenuation correction. Leveraging a Multiview Ensemble Conditional Diffusion Model, this technology promises safer, more cost-effective, and highly accurate diagnostic results for brain PET scans, addressing critical limitations of current methodologies.

Executive Impact & Key Takeaways

The Multiview Ensemble Conditional Diffusion Model significantly advances PET imaging by offering a CT-less attenuation correction. This innovation leads to substantial benefits in patient safety, operational efficiency, and diagnostic accuracy, making advanced PET diagnostics more accessible and reliable for healthcare enterprises.

0 Avg. Error in PET Quantification
0 Mean Absolute Error on CT Images
0 Head Scans Validated
0 Orthogonal Views Processed
  • CT-Less Attenuation Correction: Proposes a novel method for PET imaging that eliminates the need for co-computed CT imaging, reducing patient radiation exposure and equipment costs.
  • Multiview Ensemble DDPM: Utilizes a Conditional Denoising Diffusion Probabilistic Model (DDPM) that processes non-attenuation-corrected PET images from three orthogonal views (transverse, sagittal, coronal).
  • Artifact Reduction via Majority Voting: Employs an ensemble majority voting process to combine predictions from the three models, effectively detecting and eliminating artifacts and improving consistency.
  • High-Resolution Pseudo-CT Generation: Successfully generates high-quality pseudo-CT (pCT) images used to create accurate attenuation maps, improving quantitative PET results.
  • Improved Diagnostic Accuracy: Achieves a mean absolute error of 32 ± 10.4 HU on CT images and an average error of (1.48 ± 0.68)% across ROIs in reconstructed PET images, comparable to true CT-based correction.
  • Broader Applicability: This method is especially beneficial for scanners lacking traditional attenuation correction capabilities and offers a robust solution against patient movement and misregistration.

Deep Analysis & Enterprise Applications

Select a topic to dive deeper, then explore the specific findings from the research, rebuilt as interactive, enterprise-focused modules.

Positron Emission Tomography (PET) quantification is crucial for diagnosis and treatment tracking, but attenuation — the loss of photons as they traverse biological tissues — degrades signal intensity, especially in denser regions. Inaccurate attenuation correction leads to quantification errors, misdiagnosis, and difficulty differentiating conditions. Current methods relying on Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) introduce additional radiation, potential misregistration, and high costs. Existing deep learning approaches often suffer from artifacts or mode collapse.

The proposed solution leverages a Conditional Denoising Diffusion Probabilistic Model (DDPM) with a UNet backbone. This model synthesizes pseudo-CT (pCT) images from non-attenuation-corrected (NAC) PET images. A key innovation is the use of three separate 2D models, each trained on a distinct slice orientation: transverse, sagittal, and coronal. This multiview approach enhances robustness and allows the system to capture comprehensive anatomical information.

To ensure reliability and mitigate artifacts, the pCT images generated from the three orthogonal views are combined using a pixel-by-pixel majority voting process. This process handles three scenarios: averaging values within a threshold, excluding outliers and averaging the rest, or averaging the two most similar values when all exceed the threshold. This ensemble approach significantly reduces artifacts and improves slice-to-slice consistency, crucial for medical diagnostic quality.

The method was validated on 159 head scans from a Siemens Biograph Vision PET/CT scanner. Results demonstrate strong performance: a mean absolute error of 32 ± 10.4 HU on CT images and an average error of (1.48 ± 0.68)% across all regions of interest for reconstructed PET images. Qualitatively, the generated pCTs show high visual similarity to true CTs, with the voting method effectively removing internal artifacts and improving overall image quality, especially in the brain region.

1.48% Average Error in PET Quantification (across ROIs)

Advantages of Multiview Ensemble DDPM vs. Traditional Methods

Feature Traditional CT/MRI Multiview Ensemble DDPM
Radiation Exposure High (CT)
  • None (CT-less)
Misregistration Risk High (PET/CT)
  • None (PET-aligned)
Equipment Cost High (dedicated CT/MRI)
  • Reduced (PET-only)
Artifact Handling Prone to metal/movement artifacts
  • Reduced by voting, handles metal artifacts
Anatomical Information Direct from CT/MRI
  • Synthesized from PET (learning-based)
Interpretability Clear anatomical input
  • PCT modification of PET data is clear

Multiview Ensemble Diffusion Process

NAC PET Image Input
Generate 2D Slices (Transverse, Sagittal, Coronal)
DDPM Pseudo-CT Generation (per orientation)
Combine 3D Images
Majority Voting (Pixel-by-Pixel)
Final Pseudo-CT Output
PET Attenuation Correction

Impact of Patient Movement & Metal Artifacts

The research highlights that generating pCT from PET alone completely avoids misregistration issues caused by patient movement between separate CT/PET acquisitions. This ensures perfect alignment and potentially more realistic attenuation correction in cases of movement. Furthermore, the DDPM effectively mitigates metal streak artifacts (e.g., from dental fillings) often present in conventional CTs, demonstrating its ability to learn and generate clean images even when ground truth contains artifacts. This represents a significant clinical advantage in diagnostic accuracy.

Calculate Your Potential Enterprise ROI

Estimate the efficiency gains and cost savings for your organization by adopting AI-driven solutions for medical imaging.

Estimated Annual Savings
Hours Reclaimed Annually

Your AI Implementation Roadmap

A phased approach to integrate CT-less PET attenuation correction into your clinical practice, ensuring smooth adoption and maximized benefits.

Phase 1: Pilot & Integration (3-6 Months)

Establish a pilot program within a key radiology department. Integrate the Multiview Ensemble DDPM inference engine with existing PACS/RIS for seamless image processing. Conduct rigorous validation with a diverse patient cohort, including different tracers and conditions, to fine-tune model parameters and confirm performance against ground truth CTs. Develop internal training for radiologists and nuclear medicine physicians on interpreting pCT-corrected PET images. Focus on gathering user feedback for iterative improvements.

Phase 2: Scaled Deployment & Training (6-12 Months)

Expand deployment across multiple PET imaging centers within the enterprise. Implement comprehensive training programs for all relevant clinical staff, emphasizing the benefits of CT-less attenuation correction and handling edge cases. Develop robust monitoring systems for continuous quality assurance and performance tracking. Explore integration with AI-powered diagnostic support tools to further enhance diagnostic capabilities. Begin planning for regulatory submissions if required for broader adoption.

Phase 3: Advanced Optimization & Research (12+ Months)

Continuously monitor and update the model based on new data and advancements in diffusion models. Investigate the model's performance on more challenging pathologies or patient demographics not covered in initial training. Explore possibilities for real-time pCT generation and integration into new PET scanner generations. Participate in research collaborations to publish findings, establish best practices, and contribute to the broader scientific community, solidifying leadership in AI-driven medical imaging.

Ready to Transform Your Medical Imaging?

Connect with our AI specialists to discuss how CT-less attenuation correction can revolutionize your PET workflows, improve patient care, and drive operational efficiency.

Ready to Get Started?

Book Your Free Consultation.

Let's Discuss Your AI Strategy!

Lets Discuss Your Needs


AI Consultation Booking